What each part of a beat is, its usual normal value, and what it represents.
This page is a teaching tool, not clinical guidance.
?
Test yourself
Short drills on a teaching trace: find a part, measure an interval, work out the rate, estimate the axis, or spot an abnormal beat.
See it in 3D
Watch how these waves are written as the impulse travels through a 3D heart, and how each lead sees that same beat. Coming soon.
Coming soon
One labelled beat
Hover a wave or segment to preview it; click the trace to lock, and click again to unlock. Use the brackets under the paper for the PR, QT and RR intervals, or use the buttons.
About the paper
25 mm/s paper speed0.04 s 1 small square (1 mm)0.20 s 1 large square (5 mm)10 mm/mV calibration
Read an ECG step by step
Once you can name the parts of a beat, read a tracing in this order: rate, then rhythm, then axis. The PR, QRS, QT and QTc intervals are covered on the labelled beat and in the normal values table at the bottom of the page.
1. Rate
On standard paper (25 mm/s), a 10-second lead II rhythm strip is 50 large squares long. For a regular rhythm, rate = 300 / the number of large squares between two R waves (or 1500 / small squares). For an irregular rhythm, number of QRS complexes in 10 s × 6.
Strip 1 · 10 s strip
Scroll the strip sideways if you cannot see all 10 seconds.
Click each R wave to count it. You can also focus the strip, move a marker, and press Enter.
Usual normal
Adult rate 60 to 100 /min.
Why it matters clinically
A rate under 60 /min is bradycardia; over 100 /min is tachycardia.
An irregularly irregular rate, with no P waves, occurs in atrial fibrillation.
Ask two questions. Is the rhythm regular or irregular? And is there a P wave before every QRS? March the calipers from R to R: if they keep landing on each R wave, the rhythm is regular. A regular rhythm with a P wave before every QRS is consistent with sinus rhythm. An irregularly irregular rhythm with no P waves is atrial fibrillation.
Strip 1
Scroll the strip sideways if you cannot see all 6 seconds.
Usual normal
Sinus rhythm is regular, at 60 to 100 /min in adults, with a P wave before every QRS and a constant PR interval. P waves are upright in I and II, and inverted in aVR.
Why it matters clinically
A P wave before every QRS, with a stable PR interval, is consistent with sinus rhythm.
Absent P waves and an irregularly irregular QRS rhythm occur in atrial fibrillation.
Cardiac axis is the net direction of ventricular depolarisation in the frontal plane. Usual normal is -30° to +90°. Drag the arrow on the hexaxial wheel, or use the buttons and arrow keys, and watch leads I, II and aVF change.
How to read the axis
Look at leads I and aVF (the quadrant method). A net-positive QRS means the mean QRS vector points towards that lead's positive pole. On the hexaxial system, lead I's positive pole is at 0° and aVF's is at +90°, so the two leads split the frontal plane into four quadrants:
I and aVF both positive: the axis is between 0° and +90° (normal).
I positive and aVF negative: the axis is between 0° and -90° (could still be normal, or left axis deviation).
I negative and aVF positive: the axis is between +90° and +180° (right axis deviation).
I and aVF both negative: an extreme (northwest) axis.
Then look at lead II, to separate a still-normal axis from left axis deviation. Lead II's positive pole is at +60°. The line perpendicular to lead II is at -30°, which is the usual lower limit of a normal axis. If lead II is net-positive, the mean vector still points towards +60°, so the axis is to the right of -30° and remains normal. If lead II is net-negative, the vector points away from +60° and the axis is less than -30° (left axis deviation).
Optionally, find an isoelectric lead and go perpendicular to it. A lead is isoelectric when the QRS has roughly equal positive and negative area, which means the mean vector is at right angles to that lead. Move 90° from that lead, towards the leads that are net-positive, and read the angle on the hexaxial wheel. This refines the estimate once the quadrant is known.
Then have a go at a tracing below: set the arrow to your estimate and check. Answers are marked by category (normal, left axis deviation, right axis deviation, or extreme), not by the exact degree. The exact degree is shown after you check.
Each sector has its own pattern. The thicker outline is the region the arrow sits in.
Leads I, II and aVF share one amplitude scale, so a near-isoelectric lead looks small.
Practise the axis
Here are leads I, II and aVF from a teaching tracing. Drag the arrow on the wheel to the category you think is present (normal, left axis deviation, right axis deviation, or extreme), then check. You can also use the arrow keys (hold Shift for 5° steps). The exact degree is shown after you check.
Set the arrow to the QRS axis, then press Check.
Strip 1
Leads I, II and aVF share one amplitude scale, so a near-isoelectric lead looks small. Polarities are shown after you check.
Usual normal
QRS axis between -30° and +90°. Left axis deviation is less than -30°. Right axis deviation is greater than +90°. An extreme (northwest) axis is when leads I and aVF are both negative.
Why it matters clinically
Left axis deviation can be seen in left ventricular hypertrophy, left bundle branch block, inferior infarction, and left anterior fascicular block.
Right axis deviation can be seen in right ventricular hypertrophy, acute right ventricular strain (for example pulmonary embolism), and chronic lung disease.
The PR segment (the flat line between the P wave and the QRS) is covered on the labelled beat. The small U wave after the T wave is included there too, but it is not needed to read a basic ECG.
QTc
You are not expected to calculate QTc. The uncorrected QT shortens as the heart rate rises, so the monitor reports a rate-corrected value. Assume the machine-reported QT is the corrected QTc, and interpret that number.
Usual normal: under 440 ms in men and under 460 ms in women. A QTc over 500 ms carries a high risk of torsades de pointes. Do not use a single QTc value alone to make clinical decisions.
Klabunde RE. CV Physiology: Electrocardiogram (EKG, ECG) (revised 1 November 2023). Used for the physiology of each wave and interval, including the ST segment as the action potential plateau.
Hampton J. The ECG Made Easy. Cited for the common UK teaching figure of a QRS under 0.12 s.
The beat is a synthetic teaching trace from a simple vector model, not a patient recording. Paper scale is the standard 25 mm/s and 10 mm/mV.