Learn from the source
Official RCUK posters. Open to visit the resus.org.uk links.
These cases are marked against the Resuscitation Council UK algorithm posters. Visit the official RCUK website at least once and read those posters, plus the ALS course information, rather than practising only on this page.
Not affiliated with or endorsed by Resuscitation Council UK.
- RCUK 2025 Adult Advanced Life Support guidelines (opens in a new tab)
- RCUK 2025 Adult ALS algorithm poster (PDF, opens in a new tab)
- RCUK Adult tachyarrhythmia algorithm V3 March 2026 (PDF, opens in a new tab)
- RCUK 2025 Adult bradyarrhythmia algorithm poster (PDF, opens in a new tab)
- RCUK ALS 2-day course: what the course and assessment look for (opens in a new tab)
- RCUK official guidance on anaphylaxis (opens in a new tab). None of the cases on this page is an anaphylaxis scenario. The algorithm poster published on the RCUK site is still the 2021 version: RCUK anaphylaxis algorithm 2021 (PDF, opens in a new tab).
Simulation for teaching, not clinical guidance.
Some doses and regimens, including procainamide, the isoprenaline infusion rate and the potassium arrest bolus wording, are pending anaesthetist review. Requiring a charge-then-all-clear sequence before a synchronised shock is a teaching choice that mirrors the unsynchronised ALS defibrillation sequence; the tachyarrhythmia algorithm says synchronised cardioversion but does not spell out that charge step. Follow local protocol.
How scenarios work
- Pick a listed case, or choose Random scenario. Random picks from all of the cases in the list. The name of a random case is revealed in the debrief, not while you are playing.
- Read the patient and the monitor, then choose actions in the order you would in real life. Use Identify reversible causes and Ask for / check when you need a list of causes or a test result. Each opens as a pop-up, so you do not have to scroll the actions list. Requested results, and Cycle NIBP now, appear after a short real-time delay and do not advance the simulated clock. You can keep treating while they are pending. After the first Cycle NIBP, the cuff then repeats every 2 minutes of simulated time; a further Cycle NIBP now resets that interval. Nothing you should have to request is shown up front.
- CPR for 2 minutes performs two minutes of CPR and shows the rhythm on the monitor. Skip time only advances the clock and does not count as an action. Check rhythm and pulse is a separate step.
- With Show solution off, feedback still gives a short reason when an action is not quite or partly right, and a one-line reason if a dangerous error ends the case. It will not show the full model answer or tell you the next step.
- If a key step is overdue you will get escalating nudges. After the third nudge the case ends. The debrief names the missed step and the correct action; the live nudges stay vague.
- Call the reg gives a hint. Each call deducts 0.5 from the decision score, with a minimum of 0.
- Show solution is off by default. Turn it on for more guidance, including why the rhythm changed and the guideline link.
- The debrief shows your score, what you missed, and the guideline for each decision.
- An unsynchronised shock in a patient with a pulse ends the case immediately, whether Show solution is on or off, with the words Patient harmed: scenario ended and a short reason. It would fail the ALS assessment. Other dangerous errors (for example CPR in a patient with a pulse, or shocking asystole) end the case immediately when Show solution is off; with Show solution on, those are marked Not quite and the case continues. The debrief explains why.
- Restart starts the same case again.
Choose a scenario
Acknowledgements: Scenario design informed by testing and feedback from Inchan Cho (Medical Student, GKT School of Medicine).
Scenario
Time 00:00
Pending results
Actions
What do you do next?
Event log
Identify reversible causes
Pick the cause that fits this case. Wrong picks are marked Not quite.
Ask for / check
Values appear only when you request them. Results, and Cycle NIBP now, take a few seconds of real time and do not advance the simulated clock, so requesting a test will not run the case out of time. You can keep treating while they are pending, and more than one request can be pending at once. The NIBP starts blank until the first cycle; after that it auto-cycles every 2 minutes of simulated time, and a further Cycle NIBP now resets the interval.
Drugs and fluids
Choose the drug, then the dose and route. Nothing is given until you press Give. Opening this panel does not advance the clock. Some doses and regimens, including procainamide, the isoprenaline infusion rate and the potassium arrest bolus wording, are pending anaesthetist review. Requiring a charge-then-all-clear sequence before a synchronised shock is a teaching choice that mirrors the unsynchronised ALS defibrillation sequence; the tachyarrhythmia algorithm says synchronised cardioversion but does not spell out that charge step. Follow local protocol.
Teaching tool, not clinical guidance. Management is marked against the RCUK algorithm posters. Guideline and BNF prose is used only as debrief teaching notes and is labelled as such.